------------------------------------------------------------------------- Ademco Contact/Point ID Format Bulletin 1032 1/11/01 Copyright (C) 1999, Coastal Security Systems, Inc. All Rights Reserved ------------------------------------------------------------------------- This format contains a four digit account number, a three digit alarm code which is pre-defined by Ademco, a pin status which can either be alarm or restore, a two digit area number and a three digit zone or user number. It can be depicted as follows: AAAA P CCC XX ZZZ where AAAA is the account number, P is the pin status (alarm or restore), CCC is the alarm code which is pre-defined by Ademco (you cannot program it), XX is the dialer group, partition or area number, and ZZZ is the zone or user number. The central station computer decodes contact id signals and provides the central station operator with default alarm handling instructions which are fully described below. If you are satisfied with the default instructions you need not furnish any signal information for the account. If you wish to modify the default instructions you need only furnish information for the signals you wish to modify. It is mandatory that the subscriber record contains the correct dispatch agencies for police, fire and medical alarms. If the account contains NFPA in the permanent comments field, then FIR, TAM, SUP, and TBL signals are handled as follows and not according to the tables below: FIR send fire agency, send 1 hour dealer runner, notify callout, verify TAM verify, send 1 hour runner SUP verify, send 1 hour runner TBL send 4 hour runner Note that the verify step for an NFPA FIR signal is for notification to the premises that dispatch has already been done. No cancellation request of a FIR signal received on an NFPA account will be accepted by the central station. The following tables show the alarm types, descriptions and central station procedures for all other contact id signals: ----------------------------- Medical and Personal Emegency 100 MED-AUD verify, dispatch paramedics, notify callout 101 SPC-AUD (personal emergency) verify, dispatch paramedics, notify callout 102 SPC-SIL (fail to report in) verify, notify callout ----------------------------- Fire Alarms 110 FIR-AUD verify, dispatch fire dept, notify callout 111 FIR-AUD (smoke) verify, dispatch fire dept, notify callout 112 FIR-AUD (combustion) verify, dispatch fire dept, notify callout 113 FIR-AUD (waterflow) verify, dispatch fire dept, notify callout 114 FIR-AUD (heat) verify, dispatch fire dept, notify callout 115 FIR-AUD (pull station) verify, dispatch fire dept, notify callout 116 FIR-AUD (duct detector) verify, dispatch fire dept, notify callout 117 FIR-AUD (flame detector) verify, dispatch fire dept, notify callout 118 TBL-SIL (near alarm) log (will appear on trouble signal report) ----------------------------- Panic Alarms 120 PAN-SIL verify, dispatch police 121 AMB-SIL verify, dispatch police 122 HUP-SIL verify, dispatch police 123 HUP-AUD verify, dispatch police ----------------------------- Intrusion Alarms 130 BUR-AUD verify, dispatch police, notify callout 131 BUR-AUD (perimeter) verify, dispatch police, notify callout 132 BUR-AUD (interior) verify, dispatch police, notify callout 133 BUR-AUD (24-hour zone) verify, dispatch police, notify callout 134 BUR-AUD (entry/exit) verify, dispatch police, notify callout 135 BUR-AUD (day/night zone) verify, dispatch police, notify callout 136 BUR-AUD (outdoor) verify, dispatch police, notify callout 137 TAM-AUD verify, dispatch police, notify callout 138 TBL-SIL (near alarm) log (will appear on trouble signal report) 139 BUR-AUD verify, dispatch police, notify callout ----------------------------- General Alarms 140 SPC-AUD (general alarm) verify, dispatch police, notify callout 141 TBL-SIL (polling loop open) log (will appear on trouble signal report) 142 TBL-SIL (polling loop short) log (will appear on trouble signal report) 143 TBL-SIL (expansion mod fail) log (will appear on trouble signal report) 144 TAM-SIL (sensor) verify, dispatch police, notify callout 145 TAM-SIL (expansion module) verify, dispatch police, notify callout 146 BUR-SIL verify, dispatch police, notify callout ----------------------------- 24-Hour Non-Burglary 150 SPC-AUD (general alarm) verify, notify callout 151 SPC-AUD (gas detected) verify, notify callout 152 TEM-AUD (refridgeration) verify, notify callout 153 TEM-AUD (loss of heat) verify, notify callout 154 SPC-AUD (water leakage) verify, notify callout 155 TBL-AUD (foil break) verify, notify dealer 156 TBL-AUD (day trouble) verify, notify dealer 157 SPC-AUD (low gas level) verify, notify callout 158 TEM-AUD (high temperature) verify, notify callout 159 TEM-AUD (low temperature) verify, notify callout 161 SPC-AUD (air flow loss) verify, notify callout ----------------------------- Fire Supervisory 200 SUP-AUD verify, notify dealer 201 TBL-AUD (low water pressure) verify, notify dealer 202 TBL-AUD (low CO2) verify, notify dealer 203 SUP-AUD (gate valve tamper) verify, notify dealer 204 TBL-AUD (low water level) verify, notify dealer 205 FIR-AUD (pump activated) verify, dispatch fire dept, notify callout 206 TBL-AUD (pump failure) verify, notify dealer ----------------------------- Trouble Signals 300 TBL-SIL log (will appear on trouble signal report) 301 TBL-SIL (ac power loss) log (will appear on trouble signal report) 302 TBL-SIL (low system battery) log (will appear on trouble signal report) 303 TBL-SIL (ram checksum bad) log (will appear on trouble signal report) 304 TBL-SIL (rom checksum bad) log (will appear on trouble signal report) 305 LOG-SIL (system reset) log 306 TAM-SIL (panel prog change) log 307 TBL-SIL (self test failure) log (will appear on trouble signal report) 308 TBL-SIL (system shutdown) log (will appear on trouble signal report) 309 TBL-SIL (battery test fail) log (will appear on trouble signal report) 310 TBL-SIL (ground fault) log (will appear on trouble signal report) 320 TBL-SIL (sounder/relay) log (will appear on trouble signal report) 321 TBL-SIL (bell 1) log (will appear on trouble signal report) 322 TBL-SIL (bell 2) log (will appear on trouble signal report) 323 TBL-SIL (alarm relay) log (will appear on trouble signal report) 324 TBL-SIL (trouble relay) log (will appear on trouble signal report) 325 TBL-SIL (reversing relay) log (will appear on trouble signal report) 330 TBL-SIL (system peripheral) log (will appear on trouble signal report) 331 TBL-SIL (polling loop open) log (will appear on trouble signal report) 332 TBL-SIL (polling loop short) log (will appear on trouble signal report) 333 TBL-SIL (expansion module) log (will appear on trouble signal report) 334 TBL-SIL (repeater failure) log (will appear on trouble signal report) 335 TBL-SIL (printer paper out) log (will appear on trouble signal report) 336 TBL-SIL (printer failure) log (will appear on trouble signal report) 337 TBL-SIL (exp mod dc loss) log (will appear on trouble signal report) 338 TBL-SIL (exp mod low battery) log (will appear on trouble signal report) 339 RES-SIL (exp mod reset) log 341 TAM-SIL (expansion module) verify, dispatch police, notify callout 350 TBL-SIL (communication fail) notify dealer 351 TBL-SIL (telco line 1) notify dealer 352 TBL-SIL (telco line 2) notify dealer 353 TBL-SIL (long range radio) notify dealer 354 TBL-SIL (fail to communicate) log (will appear on trouble signal report) 355 TBL-SIL (lost radio supervsn) notify dealer 357 TBL-SIL (radio antenna VSWR) notify dealer 356 TBL-SIL (lost polling) notify dealer 370 TBL-SIL (protection loop) log (will appear on trouble signal report) 371 TBL-SIL (prot. loop open) log (will appear on trouble signal report) 372 TBL-SIL (prot. loop short) log (will appear on trouble signal report) 373 TBL-SIL (fire trouble) notify dealer 374 TBL-AUD (exit error) verify, notify callout 380 TBL-SIL (sensor) log (will appear on trouble signal report) 381 TBL-SIL (rf supervision) log (will appear on trouble signal report) 382 TBL-SIL (rpm supervision) log (will appear on trouble signal report) 383 TAM-SIL verify, dispatch police, notify callout 384 TBL-SIL (rf low battery) log (will appear on trouble signal report) 385 TBL-SIL (smoke det hi sens) log (will appear on trouble signal report) 386 TBL-SIL (smoke det low sens) log (will appear on trouble signal report) 387 TBL-SIL (detector hi sens) log (will appear on trouble signal report) 388 TBL-SIL (detector low sens) log (will appear on trouble signal report) ----------------------------- Openings and Closings Note that an event which is defined as an opening will become a closing if a restore status is received. For example a code 400 alarm is an opening and a code 400 restore is a closing. 400 OPN-SIL log 401 OPN-SIL (by user) log 402 OPN-SIL (group) log 403 OPN-SIL (automatic) log 404 LTO-SIL verify, notify callout 405 OPN-SIL (deferred) log 406 CAN-SIL log 407 OPN-SIL (remote) log 408 OPN-SIL (quick arm) log 409 OPN-SIL (keyswitch) log ----------------------------- Remote Access 411 LOG-SIL (callback requested) log 412 LOG-SIL (successful access) log 413 LOG-SIL (unsuccessful access) log 414 LOG-SIL (system shutdown) log 415 LOG-SIL (dialer shutdown) log ----------------------------- Access Control 421 LOG-SIL (access denied) log 422 LOG-SIL (access permitted) log ----------------------------- Exception Open/Close 441 CLO-SIL (stay mode) log 450 OPN-SIL (exception) verify, notify callout 451 OPN-SIL (early) verify, notify callout 452 OPN-SIL (late) verify, notify callout 453 LTO-SIL verify, notify callout 454 LTC-SIL verify, notify callout 455 LTC-SIL (auto arm failed) verify, notify callout 456 FAR-SIL (partial arm) log 457 BUR-AUD (exit error) verify, notify callout 458 OPN-SIL (user on premises) verify 459 BUR-SIL (recent close) verify, dispatch, notify callout ----------------------------- Disables/Bypasses 520 SUP-SIL (sounder relay disabled) log 521 SUP-SIL (bell 1 disabled) log 522 SUP-SIL (bell 2 disabled) log 523 SUP-SIL (alarm relay disabled) log 524 SUP-SIL (trouble relay disabled) log 525 SUP-SIL (reversing relay disabled) log 551 SUP-SIL (dialer disabled) log 552 SUP-SIL (radio xmttr disabled) log 570 BYP-SIL (zone or sensor) log 571 BYP-SIL (fire) log 572 BYP-SIL (24 hour zone) log 573 BYP-SIL (burglary) log 574 BYP-SIL (group) log 575 BYP-SIL (swinger bypassed) log (appears on trouble signal report) ----------------------------- Tests and Miscellaneous 601 TST-SIL (manual) log 602 NUL-SIL (periodic) update last signal field 603 NUL-SIL (periodic - radio) update last signal field 604 TST-SIL (fire alarm) log 605 LOG-SIL (status report to follow) log 606 SPC-SIL (listen in to follow) log 607 TST-SIL (walk test mode entered) log 608 TST-SIL (system remains in troubl) log (appears on trouble signal report) 609 LOG-SIL (video transmitter active) log 611 TST-SIL (point tested ok) log 612 FTT-SIL (point not tested) log (appears on trouble signal report) 621 LOG-SIL (event log reset) log 622 TBL-SIL (event log 50% full) log (appears on trouble signal report) 623 TBL-SIL (event log 90% full) notify dealer 624 TBL-SIL (event log overflow) log (appears on trouble signal report) 625 LOG-SIL (time/date reset) log 626 TBL-SIL (time/date inaccurate) log (appears on trouble signal report) 627 LOG-SIL (program mode entry) log 628 LOG-SIL (program mode exit) log 630 LOG-SIL (schedule change) log 631 LOG-SIL (exception sched change) log 632 LOG-SIL (access schedule change) log